Hammer Coil - Printronix P9012 Maintenance Manual

Multifunction line printer
Table of Contents

Advertisement

Hammer Coil

(Figure 6–9)
Removal
1. Remove the hammer spring at the faulty coil location as described on
page 6–22.
2. Carefully separate the two coil leads (1) from the connector (2) as
follows:
Do not move the connector releasing tabs any more than necessary to
remove the leads. Damage to the connector will result.
a. Using an X–acto knife or other small tool, push down the releasing
b. Withdraw the coil lead and its terminal (4).
3. Remove the two screws (5) on the coil lead clamp (6) that holds the leads
of the coil being removed.
4. Gently pull two coil leads from the coil lead bracket (7).
5. Remove two screws (8), washers (9), and the coil clamp plate (10).
6. Separate the coil (11) from the pole pins (12).
6–28
tab (3).
CAUTION
Replacement Procedures