Ribbon Tracking Check And Adjustment - Printronix P9012 Maintenance Manual

Multifunction line printer
Table of Contents

Advertisement

Alignments and Adjustments
This chapter contains the alignment and adjustment procedures done at
the field service maintenance level.

Ribbon Tracking Check and Adjustment

1. Make sure paper is loaded in the printer and a full ribbon spool is on the
right. Turn power on and open the printer top cover.
2. Set the forms thickness adjustment lever (1) to any position between "A"
and "B." Make sure no error indications appear.
3. Refer to the P9012 User's Manual and command a shuttle/ribbon
self–test. Shuttle action and ribbon motion should begin.
4. On either the left or right ribbon guide (2), momentarily short across the
skids (3).
5. Let the ribbon run completely out of the spool. Verify the ribbon is
centered in the guide. If not, follow these steps:
a. Loosen two screws (4) with washers (5) until the left ribbon guide
b. Pivot the guide until the ribbon tracks in the center.
c. Tighten two screws.
d. Verify that the ribbon is centered and winds up without interference
6. The spool should automatically reverse. If it does not, follow these steps:
a. Replace the ribbon (page 6–8). Rerun the test.
b. If there is still an error, check the cabling.
c. If ribbon tracking is still unsuccessful, replace the ribbon deck
5–2
can be rotated about the guide post (6).
on the left spool.
assembly (page 6–8).
(Figure 5–1)
Alignments and Adjustments

Advertisement

Table of Contents
loading

Table of Contents