MEASURE STATUS
GEAR LEVER
GEAR
POSITION
POSITION
P
-
R
Reverse Gear
N
Neutral Gear
Gear 1
Gear 2
D
Gear 3
Gear 4
• In accordance with the shown status of standard fluid pressure measurement table, measure the fluid pressure
of each measurement port. The measurement of each port should be within the standard range.
• If some measurement values is beyond the standard range, please refer to the fluid pressure measurement and
diagnosis table for causes.
Is the check result normal?
Yes
>>
Go to step 5 for disc or plate abrasion.
No
>>
Go to the next step.
3.
CHECK VALVE BODY ASSEMBLY AND FLUID PUMP AND PIPELINE
• Turn the ignition switch off.
• Disassemble and repair F4A4 automatic transaxle assembly (See Automatic Transaxle Removal & Installation in
Section 08 Transaxle & Transfer Case).
• Check valve body and fluid pump and pipeline.
Is the check result normal?
Yes
>>
Go to the next step.
No
>>
Replace damaged components and low speed clutch and reverse gear clutch for low pressure burned.
4.
COMPRESSED AIR TEST
• Check low speed clutch system: Low speed clutch piston should be active and maintain pressure when com-
pressed air is applied to the fluid hole.
• Check reverse gear clutch system: Reverse gear clutch piston should be active and maintain pressure when
compressed air is applied to the fluid hole.
Is the check result normal?
Yes
>>
Go to the next step for disc or plate abrasion.
No
>>
Replace damaged components and low speed clutch and reverse gear clutch for low pressure burned.
234
08–
DIAGNOSIS & TESTING
ENGINE
DECELERATION
SPEED
CLUTCH
(RPM)
PRESSURE
2,500
-
2,500
-
1,270 - 1,770
2,500
-
1,010 - 1,050
2,500
(146 - 152)
2,500
-
590 - 690 (85 -
2,500
100)
2,500
-
STANDARD FLUID PRESSURE KPA (PSI)
REVERSE
OVERDRIVE
GEAR
CLUTCH
CLUTCH
PRESSURE
PRESSURE
-
-
-
-
-
-
-
-
-
590 - 690
-
(85 - 100)
590 - 690
-
(85 - 100)
Chery Automobile Co., Ltd.
LOW/
SECONDARY
REVERSE
GEAR
BRAKE
CLUTCH
PRESSURE
PRESSURE
310 - 390
-
(45-56)
1,270 - 1,770
-
310 - 390 (45
-
- 56)
1,010 - 1,050
-
(146 - 152)
1,010 - 1,050
-
(146 - 152)
-
-
590 - 690 (85
-
- 100)
TORQUE
CONVERTER
PRESSURE
250 - 390 (36
- 56)
500 - 700 (73
- 101)
250 - 390 (36
- 56)
500 - 700 (73
- 101)
500 - 700 (73
- 101)
450 - 650 (65
- 94)
450 - 650 (65
- 94)