4.
CHECK FUEL LEVEL SENSOR CIRCUIT FOR OPEN OR SHORT
• Turn ignition switch off.
• Disconnect the IC connector.
• Check harness for a short to ground.
FUEL LEVEL SENSOR
TERMINAL
1
• Check for continuity between the following terminals:
FUEL LEVEL
SENSOR
IC TERMINAL
TERMINAL
1
• Continuity should exist.
• Check the harness for a short to power.
Is the check result normal?
Yes
>>
Go to the next step.
No
>>
Repair or replace the fuel level sensor supply circuit as necessary.
5.
CHECK FUEL LEVEL SENSOR GROUND CIRCUIT
• Using a 12 V test light connected to battery (+), probe fuel level sensor ground circuit.
Does the test light illuminate brightly?
Yes
>>
Go to the next step.
No
>>
Repair or replace the fuel level sensor ground circuit for an open.
82
15–
DIAGNOSIS & TESTING
GROUND
Ground
CONTINUITY
21
Yes