Good Decode Reads
Good Decode Reads
Usage:
This is a very useful feature to increase reliability of reads for symbolo-
gies that do not have internal error checking such as Pharmacode.
Definition:
The number of decodes (from 1 to 31) required per symbol before a sym-
bol's decoded data is sent. It requires the scanner to successfully decode
a symbol a designated number of times (not necessarily consecutively)
before it is sent. If it doesn't achieve the number of good reads during
the read cycle, then a noread will be sent.
Note: Higher settings will decrease throughput speed.
Serial Cmd:
<K221, good decode
Default:
1
Options:
1 to 31
When setting up, be sure to determine if the scanner's scan rate is capable of
Note
:
scanning your longest symbol the required number of times.