Defaulting/Saving/Initializing
Restore Microscan Defaults to Active Memory and for Power-on
Defaulting the scanner to Microscan
Caution
:
default settings will overwrite user-saved settings.
• Restores Microscan defaults to memory.
• Restores Microscan defaults to user-saved set-
tings for power-on.
• Initializes serial configuration commands in
active memory and resets counters to zero.
By Serial Command
Send
<Zd>
command to the scanner.
By ESP
1.
in the configuration window and select
Right-click
2.
and select
Right-click
By Hardware Default
If a software default reset is not possible, it may be necessary to reset the scanner by
shorting (connecting) specific pins. This procedure has the same effect as the <Zd>
software command.
1. Apply power to the scanner.
2. If using an IB-131, locate pins 7 and 11 on the host connector. (see
Interface Module" on page
Caution: Be certain that the correct pins are located. Connecting the wrong pins
could cause serious damage to the unit.
3. Momentarily connect these wires (or pins) and listen for a series of short beeps.
4. Within 3 seconds, connect them again. A longer beep should be heard. If not,
repeat the process.
A-22
MS-9 Scanner User's Manual
and
Save to Reader
A-10).
Initialize
<
>
Zd
Memory
User-Saved
Settings
Default all ESP
Send and
Save.
Active
Microscan
Defaults
Settings.