Warning Messages
Laser Low
When enabled, a message is transmitted whenever the laser current falls below a fac-
tory-calibrated reference value which cannot be altered. The message repeats once
every 30 minutes until the condition is corrected.
Laser Low Status
Usage:
Alerts the user to impending laser failure. (Contact your service repre-
sentative.)
Definition:
Enables the Laser Low message.
Serial Cmd:
<K400,warning message status,laser high
novram corrupt warning status>
Default:
Enabled
Options:
0 = Disabled
Laser Low Message
Definition:
Defines the Laser Low message.
Serial Cmd:
<K405,laser low
Default:
LOW_LASER
Options:
Any 1 to 10 character ASCII string except NUL, <, or >.
Note: If you suspect that erroneous defaults are occurring, enable NOVRAM Mes-
sages by sending <K400,1,,,1>. This will allow the NOVRAM messages, if present, to
be viewed.
9-8
MS-9 Scanner User's Manual
1 = Enabled
message>
status,laser low
status,