Defaulting/Saving/Initializing
Initializing
Initializing occurs whenever any command or set of commands is implemented.
Initializing is a part of all save and default functions. It is also used as a follow-on to
implement serial configuration commands.
• Initializes serial configuration commands into
active memory and resets counters to zero.
• Does not save settings for power-on.
By Serial Command
Send
after a serial configur ation command or a
<A>
string of serial configuration commands, for exam-
ple, <K141,d1><A>.
By ESP
in the configuration window and select
Right-click
This will initialize all serial configuration changes that have been made in the current
ESP session.
Loss of Communications
Making changes to communications with the host such as
LRC, etc. without corresponding changes in linked device(s) can result in the loss
Bits,
of menu access through If this should occur, you should restore the scanner's defaults.
(See
"Defaulting" on page
A-24
MS-9 Scanner User's Manual
A-21.)
<
>
A
Initialize
Active
Memory
User-Saved
Settings
Save to Reader, Send No Save.
Baud Rate, Parity, Stop
Microscan
Defaults