Good Decode Reads

Good Decode Reads

Note
When setting up, determine if the scanner's scan rate is capable of scanning
:
your longest symbol the required number of times.
Decodes Before Output
Definition:
The number of decodes (from 1 to 31) required per symbol before a
symbol's decoded data is sent. It requires the scanner to successfully
decode a symbol a designated number of times before it is sent. If it
doesn't achieve the number of good reads during the read cycle, then a
noread will be sent.
Note: Higher settings will decrease throughput speed.
Usage:
This is a very useful feature to increase reliability of reads for symbolo-
gies that do not have internal error checking such as Pharmacode.
Serial Cmd:
<K221, decodes before
Default:
1
Options:
1 to 255
Consecutive Status
Definition:
When consecutive is enabled, the number set in Decodes Before Out-
put must be achieved consecutively before decoded data is sent.
When the default non-consecutive is set, whenever a cumulative num-
ber of decodes is achieved, decoded data is sent. For example, if non-
consecutive is enabled and Decodes Before Output is set to 10, then
data will be sent when the total number of decodes reaches 10 regard-
less of the number of bad reads between decodes.
Usage:
Useful when the highest level of reliability is required.
Serial Cmd:
<K221,
decodes before
Default:
Non-consecutive
Options:
0 = Non-consecutive
1 = Consecutive
MS-3 Laser Scanner User's Manual
4-14
output,consecutive status>
output,consecutive
status>