6.6.2 View/PreShot Recall, Continued
6. Press lock to exit menu on LCD controller.
6.7

VECTORSCAN (VIDEO TOUR)

When a scan receives a command to run a VectorScan, it goes to the first PreShot
programmed in the VectorScan at maximum velocity (400°/second) for the programmed
dwell time, then goes to the next PreShot in the VectorScan at the programmed velocity
for the specified dwell time, etc.
When a VectorScan is running continuously, the unit goes from the last PreShot to the
first PreShot at the programmed velocity. The amount of time the scan takes to go to
each PreShot depends on the programmed velocity and the distance to the next
PreShot's pan and tilt coordinates. The velocity is programmable from 1° to 400° per
second. The title of each PreShot, as it is viewed, is added to the video signal.
A VectorScan generally repeats continuously until an operator manually controls the
scan (pan, tilt, zoom, focus, or iris) or the scan receives a PreShot, VectorScan, PTZ
tour, or Find Home command. (Exception: there is a mode where the VectorScan will
run just once. Automatic operation stops after the last PreShot in the VectorScan is
executed.)

6.7.1 List Programmed VectorScans

A list of the programmed VectorScans can be viewed for each scan unit. The list
displays the VectorScan numbers and titles. The VectorScans cannot be edited from
this display.
If using an HJZTP controller, use the following steps to view the list of programmed
VectorScans (for the control camera displayed on the programming controller). Refer to
your controller manual for specifics when using other controllers.
1. Press and hold lock, then press F6 (menu). The LCD displays the menu selections
available. Setup will be flashing to indicate that Setup is the currently selected
option.
2. Move the joystick left and right or F3 ( ) and F4 ( ) or camera (left) and preset
(right) keys until VECT is flashing, and then press the aux key.
3. Move the joystick right until LST is flashing and then press the aux key.
4
Press the aux key to scroll through the pages of the listing. An "End of Directory"
message appears at the bottom of the last page.
5. Press the lock key when done viewing the VectorScan list.