ProSAFE M7100 Managed Switches
Term
Definition
System Time Up
How long the system had been running at the time the trap was sent.
Trap
The text of the trap message.
logging persistent
Use this command to configure the persistent logging for the switch. The severity level of logging
messages is specified at the severity level. You can specify the <severitylevel> parameter
either as an integer from 0 to 7 or symbolically through one of the following keywords:
emergency (0), alert (1), critical (2), error (3), warning (4), notice (5), info (6),
or debug (7).
Default
Disable
Format
logging persistent <severitylevel>
Mode
Global Config
no logging persistent
Use this command to disable the persistent logging in the switch.
Format
no logging persistent
Mode
Global Config
Email Alerting and Mail Server Commands
logging email
This command enables email alerting and sets the lowest severity level for which log messages
are emailed. If you specify a severity level, log messages at or above this severity level, but below
the urgent severity level, are emailed in a non-urgent manner by collecting them together until
the log time expires. You can specify the <severitylevel> parameter either as an integer
from 0 to 7 or symbolically through one of the following keywords: emergency (0), alert (1),
critical (2), error (3), warning (4), notice (5), info (6), or debug (7).
Default
Disabled; when enabled, log messages at or above severity Warning (4) are emailed
Format
logging email [<severitylevel>]
Mode
Global Config
Utility Commands
394