NETGEAR ProSAFE M7100-24X Reference Manual page 143

Prosafe m7100 managed switches command-line interface (cli) reference manual
Hide thumbs Also See for ProSAFE M7100-24X:
Table of Contents

Advertisement

ProSAFE M7100 Managed Switches
Term
Definition
Chassis ID
The type of identification used in the Chassis ID field.
Subtype
Chassis ID
The chassis of the remote device.
Port ID Subtype
The type of port on the remote device.
Port ID
The port number that transmitted the LLDPDU.
System Name
The system name of the remote device.
System
Describes the remote system by identifying the system name and versions of hardware,
Description
operating system, and networking software supported in the device.
Port Description
Describes the port in an alpha-numeric format. The port description is configurable.
System
Indicates the primary function(s) of the device.
Capabilities
Supported
System
Shows which of the supported system capabilities are enabled.
Capabilities
Enabled
Management
For each interface on the remote device with an LLDP agent, lists the type of address the
Address
remote LLDP agent uses and specifies the address used to obtain information related to the
device.
Time To Live
The amount of time (in seconds) the remote device's information received in the LLDPDU
should be treated as valid information.
The following shows example CLI display output for the command.
(Switch) #show lldp remote-device detail 0/7
LLDP Remote Device Detail
Local Interface: 0/7
Remote Identifier: 2
Chassis ID Subtype: MAC Address
Chassis ID: 00:FC:E3:90:01:0F
Port ID Subtype: MAC Address
Port ID: 00:FC:E3:90:01:11
System Name:
System Description:
Port Description:
System Capabilities Supported:
System Capabilities Enabled:
Time to Live: 24 seconds
Switching Commands
143

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prosafe m7100 series

Table of Contents