ProSAFE M7100 Managed Switches
Table 22. WEB Log Messages
Component
Message
WEB
ewaFormServe_file_upload() - Unknown
return code from tftp upload result
WEB
Web UI Screen with unspecified access
attempted to be brought up
Table 23. CLI_WEB_MGR Log Messages
Component
Message
CLI_WEB_MGR
File size is greater than 2K
CLI_WEB_MGR
No. of rows greater than allowed maximum
of XXXX
Table 24. SSHD Log Messages
Component
Message
SSHD
SSHD: Unable to create the global (data)
semaphore
SSHD
SSHD: Msg Queue is full, event = XXXX
SSHD
SSHD: Unknown UI event in message, event=
XXXX
SSHD
sshdApiCnfgrCommand: Failed calling
sshdIssueCmd.
Table 25. SSLT Log Messages
Component
Message
SSLT
SSLT: Exceeded maximum,
ssltConnectionTask
SSLT
SSLT: Error creating Secure server socket6
Cause
Unknown error returned while uploading file
using TFTP from web interface.
Failed to get application-specific
authorization handle provided to
EmWeb/Server by the application in
ewsAuthRegister(). The specified web page
will be served in read-only mode.
Cause
The banner file size is greater than 2K bytes.
When the number of rows exceeds the
maximum allowed rows
Cause
Failed to create semaphore for global data
protection.
Failed to send the message to the SSHD
message queue as message queue is full.
XXXX indicates the event to be sent
Failed to dispatch the UI event to the
appropriate SSHD function as it's an invalid
event. XXXX indicates the event to be
dispatched.
Failed to send the message to the SSHD
message queue
Cause
Exceeded maximum allowed SSLT
connections.
Failed to create secure server socket for
IPV6.
Log Messages