Transport Output Telnet - NETGEAR ProSAFE M7100-24X Reference Manual

Prosafe m7100 managed switches command-line interface (cli) reference manual
Hide thumbs Also See for ProSAFE M7100-24X:
Table of Contents

Advertisement

ProSAFE M7100 Managed Switches
Note:
If the Telnet Server Admin Mode is disabled, Telnet sessions cannot be
established. Use the ip telnet server enable command to
enable Telnet Server Admin Mode.
Default
enabled
Format
transport input telnet
Mode
Line Config
no transport input telnet
Use this command to prevent new Telnet sessions from being established.
Format
no transport input telnet
Mode
Line Config

transport output telnet

Use this command to regulate new outbound Telnet connections. If enabled, new outbound
Telnet sessions can be established until the system reaches the maximum number of simultaneous
outbound Telnet sessions allowed. An established session remains active until the session is ended
or an abnormal network error ends it.
Default
enabled
Format
transport output telnet
Mode
Line Config
no transport output telnet
Use this command to prevent new outbound Telnet connection from being established.
Format
no transport output telnet
Mode
Line Config
session-limit
Use this command to specify the maximum number of simultaneous outbound Telnet sessions. A
value of 0 indicates that no outbound Telnet session can be established.
Default
5
Format
session-limit <0-5>
Mode
Line Config
Management Commands