Power Connections To Heater (All Outdoor Models) - Bosch VJR SERIES Installation Manual

Autodome junior hd
Hide thumbs Also See for VJR SERIES:
Table of Contents

Advertisement

80
en | Preparing the Wiring
8.2.2

Power Connections to Heater (all outdoor models)

The heater in an outdoor AutoDome Junior HD unit accepts
power only from a single 24 VAC isolated power connector
(white/red and white/black wires). The heater does not accept
power via Power over Ethernet + (PoE+, IEEE 802.3at, class 4).
Figure 8.2 Power Cable
Ref. # Wire
1
2
3
WARNING!
The heater unit accepts 24 VAC, 2 A power only. Do not connect
120 V or 230 V to this heater.
To connect the power to outdoor unit heaters:
1.
2.
3.
F.01U.275.803 | 6.0 | 2012.11
24 VAC
24 VAC
User-supplied Power Supply
Locate the cable assembly with a three (3) pin mating
connector on one end and the white/red and white/black
flying leads on the other end.
Connect one lead of the ground or 24 VAC power source to
the white/black wire.
Connect one lead of the 24 VAC power source to the
white/red wire.