AutoDome Junior HD
3.
4.
12.42

Advanced Mode: Interfaces

12.43

Alarm Inputs

Select the type of input for each physical alarm. Select from
either N.O. (Normally Open) or N.C. (Normally Closed) and
provide an optional name for each input.
Alarm Input
Select N.O. if the alarm is to be triggered when the contact
closes. Select N.C. if the alarm is to be triggered when the
contact opens.
Bosch Security Systems, Inc.
Choose one of the following output commands for both
Output 1 and Output 2 settings:
None: no defined command.
Aux On: defines a standard or custom keyboard ON
command.
Refer to Section 13 Keyboard Commands by Number,
page 179, for a list of valid commands.
Note: Only commands 1, 2, 8, 18, 20, 43, 60, 80, 86
are supported. Support for the remaining commands
is scheduled for a future release.
Aux Off: defines a standard or custom keyboard OFF
command.
Refer to Section 13 Keyboard Commands by Number,
page 179, for a list of valid commands.
Note: Only commands 1, 2, 8, 18, 20, 43, 60, 80, 86
are supported. Support for the remaining commands
is scheduled for a future release.
Shot: defines a preset scene from shot 1-64.
Click Set to save and to activate the alarm rules.
Installation Manual
Configuring the AutoDome Junior HD | en 163
F.01U.275.803 | 6.0 | 2012.11