104 en | Configuring the AutoDome 800 Series
3.
4.
7.45

Advanced Mode: Interfaces

7.46

Alarm Inputs

Select the type of input for each physical alarm. Select from either N.O. (Normally Open) or
N.C. (Normally Closed) and provide an optional name for each input.
7.47

Relay

You can configure the switching behavior of the relay outputs. For each relay, you can specify
an open switch relay (normally closed contact) or a closed switch relay (normally open
contact).
You can also specify whether an output should operate as a bistable or monostable relay. In
bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set
the time after which the relay will return to the idle state.
You can select different events that automatically activate an output. It is possible, for
example, to turn on a floodlight by triggering a motion alarm and then turning the light off
again when the alarm has stopped.
Idle State
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is
to operate as an NC contact.
Operating Mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select
Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select
10 s.
Relay Follows
Select one of the following actions that the AutoDome performs after the relay is triggered:
F.01U.273.797 | 5.0 | 2012.08
Choose one of the following output commands for both Output 1 and Output 2 settings:
None: no defined command.
Alarm Relay: defines a physical connection from the open collector alarm output.
Aux On: defines a standard or custom keyboard ON command.
Refer to Section A Keyboard Commands by Number, page 116, for a list of valid com-
mands.
Note: Only commands 1, 2, 8, 18, 20, 43, 60, 78, 80, 86 are supported. Support for
the remaining commands is scheduled for a future release.
Aux Off: defines a standard or custom keyboard OFF command.
Refer to Section A Keyboard Commands by Number, page 116, for a list of valid com-
mands.
Note: Only commands 1, 2, 8, 18, 20, 43, 60, 78, 80, 86 are supported. Support for
the remaining commands is scheduled for a future release.
Shot: defines a preset scene from shot 1-99.
Click Set to save and to activate the alarm rules.
Off
Connection
Video Alarm 1
Motion Alarm 1
Local Input 1
Installation Manual
AutoDome 800 Series HD PTZ Camera