Siemens MC35 Command Set page 86

Module/terminal
Hide thumbs Also See for MC35:
Table of Contents

Advertisement

AT Command Set
Read command
Response
AT+CIND?
TA returns the status of the ME indicators.
+CIND: <ind>[,<ind>[,...]]
OK
If error is related to ME functionality
+CME ERROR: <err>
Parameter
See Test command
Write command
The Write command simply controls the registration / deregistration of indicators.
AT+CIND=
<stat>
[<stat>[,<stat>
[,...]]]
Reference
Note
GSM 07.07
Examples
at+cind?
+CIND: 5,99,1,0,0,0,0,0
OK
at+cmer=2,0,0,2
OK
+CIEV: message,0
+CIEV: battchg,5
+CIEV: signal,99
+CIEV: service,1
+CIEV: sounder,0
+CIEV: call,0
+CIEV: roam,0
+CIEV: smsfull,0
atd"0123456";
OK
+CIEV: sounder,1
+CIEV: call,1
+CIEV: sounder,0
+CIEV: call,0
NO CARRIER
at+cind=,,,0,,0
OK
atd"0123456";
OK
NO CARRIER
MC35_ATC_01_V05.00
0
Indicator is deregistered. The indicator cannot be presented as
+CIEV URC, but can be directly queried with AT+CIND?.
1
Indicator is registered, indicator event report is allowed.
The battery is either full or an external supply
source is used. The bit error rate of the signal
quality is not available (since there no call in
progress), and the ME is registered to its home
network.
Activate Indicator Event Report with at+cmer
You make a call.
A set of +CIEV URCs reports is presented
The receiver hangs up.
You deregister the indicators 'call' and
'sounder'
You make a call.
This time, no +CIEV URCs are displayed.