At&V Display Current Configuration - Siemens MC35 Command Set

Module/terminal
Hide thumbs Also See for MC35:
Table of Contents

Advertisement

AT Command Set
2.37 AT&V Display current configuration
Execute command
Response
AT&V[<n>]
TA returns the current parameter setting. The configuration varies depending on
whether or not PIN authentication has been done, or Multiplex mode has been
activated.
Parameter
<n>
Configuration
PIN entered or not required (see
without Multiplex
AT+CPIN, pg. 110)
mode or configu-
ACTIVE PROFILE:
ration on chan-
E1 Q0 V1 X4 &C1 &D2 &S0 \Q0
nel 1 if Multiplex
S0:000 S3:013 S4:010 S5:008 S6:000 S7:060
mode is enabled
S8:000 S10:002 S18:000
+CBST: 7,0,1
+CRLP: 61,61,78,6
+CR: 0
+FCLASS: 0
+CRC: 0
+CMGF: 0
+CNMI: 0,0,0,0,1
+ILRR: 0
+IPR: 0
+CMEE: 0
^SMGO: 0,0
+CSMS: 0,1,1,1
^SACM: 0,"000000","000000"
^SCKS: 0,1
+CREG: 0,1
+CLIP: 0,2
+CAOC: 0
+COPS: 0,0,"operator"
OK
Logical channels
+CRC: 0
2 and 3 (Multi-
+CMGF: 0
plex mode en-
+CNMI: 0,0,0,0,1
abled)
+ILRR: 0
+IPR: 19200
+CMEE: 0
^SMGO: 0,0
+CSMS: 0,1,1,1
^SACM: 0,"000000","000000"
^SCKS: 0,1
+CREG: 0, 1
+CLIP: 0,2
+CAOC: 0
+COPS: 0,0,"operator"
OK
Reference
Note:
MC35_ATC_01_V05.00
0 profile number
Parameter values and order are subject to change.
Page 42 of 256
Required PIN not entered
ACTIVE PROFILE:
E1 Q0 V1 X4 &C1 &D2 &S0 \Q0
S0:000 S3:013 S4:010 S5:008 S6:000 S7:060
S8:000 S10:002 S18:000
+CBST: 7,0,1
+CRLP: 61,61,78,6
+CR: 0
+FCLASS: 0
+ILRR: 0
+IPR: 0
+CMEE: 0
^SCKS: 0,1
OK
+ILRR: 0
+IPR: 19200
+CMEE: 0
^SCKS: 0,1
OK
15.07.2002