03/10 Rev. 5.05-00
SYSTEM PARAMETERS
x.xx mm
Disabled
Enabled
Easyplug
Lineprinter
Hex Dump
MLI
USER- / SERVICE MANUAL
AP 5.4 Gen II – AP 5.6
Foil end warning
AP 5.4
AP 5.6
Setting of a limit diameter for the ribbon roll. If the ribbon roll diameter falls
below the set value, the displayed message changes from...
ONLINE
X JOBS
FOLIE
X JOBS
For details refer to the parameters
SERVICE DATA > OPERATION DATA > Foil diameter
Setting range: 25.4 to 50.0 mm; Unit interval: 0.1 mm;
Default setting: 25.4 mm
Foil warn stop
AP 5.4
AP 5.6
(Default setting) Printer does not stop in case of a „Foil end warning".
If a „Foil end warning" occurs, the printer stops after the current label and
shows the status message:
PrintStatus:
5110
Foil low
Press the online button to acknowledge the message, then the feed button to
continue printing.
Print Interpret.
AP 5.4
AP 5.6
The printer uses the MONARCH LANGUAGE INTERPRETER™ to inter-
prete and process data.
Printjobs written in the Easy-Plug command language can be interpreted.
Lineprinter (or similar to Lineprinter), print-out of the print command.
Print-out in hexadecimal format.
In Lineprinter and Hex Dump, commands are printed out in the form of a list
with the character set 12.
When setting Lineprinter or Hex Dump, Easy Plug commands which have
not yet been processed are deleted!
Printjobs written in the ZPL II®
Firmware loading requires changing into EasyPlug first.
...to...
...while the display is blinking.
DP INTERFACE > Ribbon signal
1)
command language can be interpreted.
Info-Printouts & Parameters
and
52