Chapter 5 Error Messages
Execution Errors
Data out of range;
duty cycle; value clipped to ...
The square wave duty cycle is limited to values between 20% and 80% by
instrument hardware.
Data out of range;
duty cycle limited by frequency; value clipped to upper limit
The square wave duty cycle is limited to values between 40% and 60%
when the frequency is greater than 10 MHz.
Duty Cycle: 20% to 80% (frequency < 10 MHz)