IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 200

Service guide
Table of Contents

Advertisement

Table 4. SPCN Error Codes (continued)
Error Code Description
1021 00AA SPCN firmware update started
1021 1510 Power supply 1 power source failure
1021 1512 Power supply 1 non-power fault
1021 1513 Power supply 1 domain fault
1021 1514 Power supply 1 cooling fault
182
Service Guide
1011 9103 Download initialize timeout
1011 9104 Download completion timeout
1011 9105 Load damaged timeout
1011 9109 Download failure
1011 9111 Network too large for service processor
1011 9114 Firmware image corrupted
1011 9116 SCPN communication with operator panel
failure
1021 1511 Power supply 1 fault
Action/
Possible Failing FRU
Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
Primary I/O backplane
Location: U0.1-P1
1. Check for system firmware
update.
2. Call service support.
1. Reinstall system firmware
2. Primary I/O backplane
Location: U0.1-P1
1. Primary I/O operator panel
Location: U0.1-L1
2. Primary I/O backplane
Location: U0.1-P1
Information message
1. Check input power to power
supply
2. Secondary I/O power supply 1
Location: U0.2-V1
3. Secondary I/O backplane
Location: U0.2-P1
1. Secondary I/O power supply 1
Location: U0.2-V1
2. Secondary I/O backplane
Location: U0.2-P1
1. Secondary I/O power supply 1
Location: U0.2-V1
2. Secondary I/O backplane
Location: U0.2-P1
1. Secondary I/O power supply 1
Location: U0.2-V1
2. Secondary I/O backplane
Location: U0.2-P1
1. Secondary I/O power supply 1
Location: U0.2-V1
2. Secondary I/O backplane
Location: U0.2-P1

Advertisement

Table of Contents
loading

Table of Contents