Table 2. Firmware Checkpoints (continued)
Checkpoint
Description
E440
Validate NVRAM, initialize partitions
as needed
E441
Generate /options node NVRAM
configuration variable properties
E442
Validate NVRAM partitions
E443
Generate NVRAM configuration
variable dictionary words
E500
Configure remote I/O subsystem
Action/
Possible Failing FRU
1. Verify that the system firmware
levels are at the current release
levels. Update as necessary.
2. Replace primary I/O backplane
if problem persists.
See the note on page 139.
1. Verify that the system firmware
levels are at the current release
levels. Update as necessary.
2. Replace primary I/O backplane
if problem persists.
See the note on page 139.
1. Verify that the system firmware
levels are at the current release
levels. Update as necessary.
2. Replace primary I/O backplane
if problem persists.
See the note on page 139.
Suspect a system firmware
problem if problem persists. Verify
that the system firmware is at
current release level. Update
back-level system firmware.
See the note on page 139.
1. Configure I/O subsystem
2. The appearance of this code
indicates that the I/O
subsystem configuration has
started or progressed to the
point where the code can be
displayed.
See the note on page 139.