Table 6. Service Processor Error Codes. (continued)
Error Code Description
450F 288D Memory system and error code
generation/logging detected memory
riser fault
450F 2A00 Memory system and error code
generation/logging detected 6W
processor fault
450F 300A Memory system and error code
generation/logging detected 32MB
DIMM fault
450F 300B Memory system and error code
generation/logging detected 128MB
DIMM fault
450F 300C Memory system and error code
generation/logging detected 256MB
DIMM fault
450F 300D Memory system and error code
generation/logging detected 512MB
(Stacked) DIMM fault
450F 300E Memory System and error code
generation/logging detected 1GB
DIMM fault
450F 301F Memory System and error code
generation/logging detected 128MB
DIMM fault
Action/
Possible Failing FRU
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
Processor card
Location: U1.1-P1-C1
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Chapter 5. Error Code to FRU Index