Table 6. Service Processor Error Codes. (continued)
246
Service Guide
Error Code Description
406B 0223 Wire test detected memory DIMM
fault
406B 0224 Wire test detected memory DIMM
fault
406B 022D Wire test detected memory DIMM
fault
406B 0231 Wire test detected memory DIMM
fault
406B 0232 Wire test detected memory DIMM
fault
406B 0233 Wire test detected memory DIMM
fault
406B 0234 Wire test detected memory DIMM
fault
406B 023D Wire test detected memory DIMM
fault
406B 02FF Wire test detected memory on riser
card fault
406B 0300 Wire test detected processor card
fault
406B 0301 Wire test detected memory DIMM
fault
406B 0302 Wire test detected memory DIMM
fault
406B 030D Wire test detected memory DIMM
fault
406B 0311 Wire test detected memory DIMM
fault
406B 0312 Wire test detected memory DIMM
fault
406B 031D Wire test detected memory DIMM
fault
406B 0321 Wire test detected memory DIMM
fault
406B 0322 Wire test detected memory DIMM
fault
406B 032D Wire test detected memory DIMM
fault
Action/
Possible Failing FRU
Memory DIMM
Location: U1.1-P1-M1.12
Memory DIMM
Location: U1.1-P1-M1.6
Memory DIMM
Location: U1.1-P1-M1.5 x4
Memory DIMM
Location: U1.1-P1-M1.9
Memory DIMM
Location: U1.1-P1-M1.7
Memory DIMM
Location: U1.1-P1-M1.10
Memory DIMM
Location: U1.1-P1-M1.8
Memory DIMM
Location: U1.1-P1-M1.7 x4
Memory failure on riser card 1 that
cannot be automatically isolated. Go
to "MAP 1540: Minimum
Configuration" on page 113, and run
CEC drawer minimum configuration
for further isolation.
Processor card
Location: U1.1-P1-C1
Memory DIMM
Location: U1.1-P1-C1-M8
Memory DIMM
Location: U1.1-P1-C1-M1
Memory DIMM
Location: U1.1-P1-C1-M1 x2
Memory DIMM
Location: U1.1-P1-C1-M7
Memory DIMM
Location: U1.1-P1-C1-M2
Memory DIMM
Location: U1.1-P1-C1-M2 x2
Memory DIMM
Location: U1.1-P1-C1-M6
Memory DIMM
Location: U1.1-P1-C1-M3
Memory DIMM
Location: U1.1-P1-C1-M3 x2