Table 6. Service Processor Error Codes. (continued)
Error Code Description
4B29 303A Processor system and memory test
detected 1GB DIMM fault
4B29 51AA Processor system and memory test
detected 645W AC power supply fault
4B29 51AB Processor system and memory test
detected 645W DC power supply
fault
4B29 51AC Processor system and memory test
detected 595W AC power supply fault
4B29 51AD Processor system and memory test
detected 595W DC power supply
fault
4B2A 244C Processor system and self test
detected 1W processor fault
4B2A 244D Processor system and self test
detected 2W processor fault
4B2A 244E Processor system and self test
detected 4W processor fault
4B2A 244F Processor system and self test
detected 1W processor fault
4B2A 248B Processor system and self test
detected primary I/O drawer operator
panel
4B2A 24A1 Processor system and self test
detected 1W processor fault
4B2A 24A2 Processor system and self test
detected 2W processor fault
4B2A 24A3 Processor system and self test
detected 4W processor fault
4B2A 24A4 Processor system and self test
detected 6W processor fault
4B2A 25BB Processor system and self test
detected 1W processor card fault
Action/
Possible Failing FRU
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
645W AC power supply
Locations:
U1.1-V1
U1.1-V2
645W DC power supply
Locations:
U1.1-V1
U1.1-V2
595W AC power supply
Locations:
U0.1-V1
U0.1-V2
595W DC power supply
Locations:
U0.1-V1
U0.1-V2
Processor card
Location:
U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Operator panel
Location: U0.1-L1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
1W Processor card
Location: U1.1-P1-C1
Chapter 5. Error Code to FRU Index