IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 197

Service guide
Table of Contents

Advertisement

Table 4. SPCN Error Codes (continued)
Error Code Description
1011 7760 Slow fan in CEC drawer power supply 2
1011 7761 Missing fan 6 in CEC drawer power
supply 2
1011 7770 Slow CEC fan 7
1011 7771 Missing fan 7
1011 7780 Slow CEC fan 8
1011 7781 Missing fan 8
1011 7790 Slow CEC fan 9
1011 7791 Missing CEC fan 9
1011 8400 VPD configuration problem
1011 8401 VPD access problem
1011 8402 VPD access problem
1011 8403 VPD level mismatch
Action/
Possible Failing FRU
1. CEC drawer power supply 2
Location: U1.1-V2
2. CEC fan controller
Location: U1.1-X2
3. Power distribution card
Location: U1.1-X1
CEC drawer power supply 2
Location: U1.1-V2
1. Fan 7
Location: U1.1-F7
2. CEC fan controller
Location: U1.1-X2
3. Power distribution card
Location: U1.1-X1
Fan 7
Location: U1.1-F7
1. Fan 8
Location: U1.1-F8
2. CEC fan controller
Location: U1.1-X2
3. Power distribution card
Location: U1.1-X1
Fan 8
Location: U1.1-F8
1. Fan 9 (cooling unit)
Location: U1.1-F9
2. CEC fan controller
Location: U1.1-X2
3. Power distribution card
Location: U1.1-X1
Fan 9 (cooling unit)
Location: U1.1-F9
Ignore all location codes.
Go to MAP 1540 and run CEC
minimum configuration.
Ignore all location codes.
Go to MAP 1540 and run CEC
minimum configuration.
Ignore all location codes.
Go to MAP 1540 and run CEC
minimum configuration.
Ignore all location codes.
Go to MAP 1540 and run CEC
minimum configuration.
Chapter 5. Error Code to FRU Index
179

Advertisement

Table of Contents
loading

Table of Contents