Table 6. Service Processor Error Codes. (continued)
Error Code Description
4B2E 303A Processor system and scan control
routines detected 1GB DIMM fault
4B2E 51AA Processor system and scan control
routines detected 645W AC power
supply fault
4B2E 51AB Processor system and scan control
routines detected 645W DC power
supply fault
4B2E 51AC Processor system and scan control
routines detected 595W AC power
supply fault
4B2E 51AD Processor system and scan control
routines detected 595W DC power
supply fault
4B2F 244C Processor system and error code
generation/logging detected 1W
processor fault
4B2F 244D Processor system and error code
generation/logging detected 2W
processor fault
4B2F 244E Processor system and error code
generation/logging detected 4W
processor fault
4B2F 244F Processor system and error code
generation/logging detected 1W
processor fault
4B2F 248B Processor system and error code
generation/logging detected primary
I/O drawer operator panel
4B2F 24A1 Processor system and error code
generation/logging detected 1W
processor fault
4B2F 24A2 Processor system and error code
generation/logging detected 2W
processor fault
4B2F 24A3 Processor system and error code
generation/logging detected 4W
processor fault
Action/
Possible Failing FRU
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
645W AC power supply
Locations:
U1.1-V1
U1.1-V2
645W DC power supply
Locations:
U1.1-V1
U1.1-V2
595W AC power supply
Locations:
U0.1-V1
U0.1-V2
595W DC power supply
Locations:
U0.1-V1
U0.1-V2
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Operator panel
Location: U0.1-L1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Chapter 5. Error Code to FRU Index
351