IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 353

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
4B29 25BB Processor system and memory test
detected 1W processor card fault
4B29 25BD Processor system and memory test
detected 2W processor card fault
4B29 25BE Processor system and memory test
detected 4W processor card fault
4B29 25BF Processor system and memory test
detected 6W processor card fault
4B29 25CB 1W processor card fault
4B29 25EA 4W processor card fault
4B29 25EB 2W processor card fault
4B29 25F2 6W processor card fault
4B29 263D Processor system and memory test
detected dummy riser card fault
4B29 2687 Processor system and memory test
detected RIO adapter fault
4B29 271A Processor system and memory test
detected primary I/O backplane fault
4B29 271D Processor system and memory test
detected secondary I/O backplane
fault
4B29 283A Processor system and memory test
detected CEC backplane fault
4B29 285D Processor system and memory test
detected fan controller card fault
Action/
Possible Failing FRU
1W Processor card
Location: U1.1-P1-C1
2W Processor card
Location: U1.1-P1-C1
4W Processor card
Location: U1.1-P1-C1
6W Processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Replace the processor card
Location: U1.1-P1-C1
Dummy riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
RIO adapter
Location: U0.1-P1.1
Primary I/O backplane
Location: U0.1-P1
Secondary I/O backplane
Location: U0.2-P1
1. Processor card
Location: U1.1-P1-C1
2. CEC backplane
Location: U1.1-P1
Fan controller card
Locations:
U0.1-X2
U1.1-X2
Chapter 5. Error Code to FRU Index
335