Table 6. Service Processor Error Codes. (continued)
268
Service Guide
Error Code Description
406F 023D Error code generation/logging
detected memory DIMM fault
406F 02FF Error code generation/logging
detected memory on riser card fault
406F 0300 Error code generation/logging
detected processor card fault
406F 0301 Error code generation/logging
detected memory DIMM fault
406F 0302 Error code generation/logging
detected memory DIMM fault
406F 030D Error code generation/logging
detected memory DIMM fault
406F 0311 Error code generation/logging
detected memory DIMM fault
406F 0312 Error code generation/logging
detected memory DIMM fault
406F 031D Error code generation/logging
detected memory DIMM fault
406F 0321 Error code generation/logging
detected memory DIMM fault
406F 0322 Error code generation/logging
detected memory DIMM fault
406F 032D Error code generation/logging
detected memory DIMM fault
406F 0331 Error code generation/logging
detected memory DIMM fault
406F 0332 Error code generation/logging
detected memory DIMM fault
406F 033D Error code generation/logging
detected memory DIMM fault
406F 03FF Error code generation/logging
detected memory on processor card
fault
406F 3101 Error code generation/logging
detected RIO port 0 fault
Action/
Possible Failing FRU
Memory DIMM
Location: U1.1-P1-M1.7 x4
Memory failure on riser card 1 that
cannot be automatically isolated. Go
to "MAP 1540: Minimum
Configuration" on page 113, and run
CEC drawer minimum configuration
for further isolation.
Processor card
Location: U1.1-P1-C1
Memory DIMM
Location: U1.1-P1-C1-M8
Memory DIMM
Location: U1.1-P1-C1-M1
Memory DIMM
Location: U1.1-P1-C1-M1 x2
Memory DIMM
Location: U1.1-P1-C1-M7
Memory DIMM
Location: U1.1-P1-C1-M2
Memory DIMM
Location: U1.1-P1-C1-M2 x2
Memory DIMM
Location: U1.1-P1-C1-M6
Memory DIMM
Location: U1.1-P1-C1-M3
Memory DIMM
Location: U1.1-P1-C1-M3 x2
Memory DIMM
Location: U1.1-P1-C1-M5
Memory DIMM
Location: U1.1-P1-C1-M4
Memory DIMM
Location: U1.1-P1-C1-M4 x2
Memory failure on processor card
that cannot be automatically isolated.
Go to "MAP 1540: Minimum
Configuration" on page 113, and run
CEC drawer minimum configuration
for further isolation.
1. Processor card
Location: U1.1-P1-C1
2. CEC drawer backplane
Location: U1.1-P1