IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual page 275

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
406D 0223 Attention handler detected memory
DIMM fault
406D 0224 Attention handler detected memory
DIMM fault
406D 022D Attention handler detected memory
DIMM fault
406D 0231 Attention handler detected memory
DIMM fault
406D 0232 Attention handler detected memory
DIMM fault
406D 0233 Attention handler detected memory
DIMM fault
406D 0234 Attention handler detected memory
DIMM fault
406D 023D Attention handler detected memory
DIMM fault
406D 02FF Attention handler detected memory
on riser card fault
406D 0300 Attention handler detected processor
card fault
406D 0301 Attention handler detected memory
DIMM fault
406D 0302 Attention handler detected memory
DIMM fault
406D 030D Attention handler detected memory
DIMM fault
406D 0311 Attention handler detected memory
DIMM fault
406D 0312 Attention handler detected memory
DIMM fault
406D 031D Attention handler detected memory
DIMM fault
406D 0321 Attention handler detected memory
DIMM fault
406D 0322 Attention handler detected memory
DIMM fault
406D 032D Attention handler detected memory
DIMM fault
Action/
Possible Failing FRU
Memory DIMM
Location: U1.1-P1-M1.12
Memory DIMM
Location: U1.1-P1-M1.6
Memory DIMM
Location: U1.1-P1-M1.5 x4
Memory DIMM
Location: U1.1-P1-M1.9
Memory DIMM
Location: U1.1-P1-M1.7
Memory DIMM
Location: U1.1-P1-M1.10
Memory DIMM
Location: U1.1-P1-M1.8
Memory DIMM
Location: U1.1-P1-M1.7 x4
Memory failure on riser card 1 that
cannot be automatically isolated. Go
to "MAP 1540: Minimum
Configuration" on page 113, and run
CEC drawer minimum configuration
for further isolation.
Processor card
Location: U1.1-P1-C1
Memory DIMM
Location: U1.1-P1-C1-M8
Memory DIMM
Location: U1.1-P1-C1-M1
Memory DIMM
Location: U1.1-P1-C1-M1 x2
Memory DIMM
Location: U1.1-P1-C1-M7
Memory DIMM
Location: U1.1-P1-C1-M2
Memory DIMM
Location: U1.1-P1-C1-M2 x2
Memory DIMM
Location: U1.1-P1-C1-M6
Memory DIMM
Location: U1.1-P1-C1-M3
Memory DIMM
Location: U1.1-P1-C1-M3 x2
Chapter 5. Error Code to FRU Index
257

Advertisement

Table of Contents
loading

Table of Contents