Table 6. Service Processor Error Codes. (continued)
Error Code Description
4067 3282 6xx bus processor runtime
diagnostics detected primary RIO
port 1 fault
4067 3283 6xx bus processor runtime
diagnostics detected primary RIO
ports fault
4067 3284 6xx bus processor runtime
diagnostics detected PCI controller
PHB0 fault
4067 3285 6xx bus processor runtime
diagnostics detected PCI controller
PHB1 fault
4067 3286 6xx bus processor runtime
diagnostics detected PCI controller
PHB2 fault
4068 0001 Other bus processor runtime
diagnostics detected CEC backplane
fault
4068 0003 Other bus processor runtime
diagnostics detected processor fault
4068 0009 Other bus processor runtime
diagnostics detected memory fault
4068 00A0 Other bus processor runtime
diagnostics detected service
processor firmware fault
4068 00A1 Other bus processor runtime
diagnostics detected system firmware
fault
4068 00A2 Other bus processor runtime
diagnostics detected service
processor firmware (processor
runtime diagnostics) fault
Action/
Possible Failing FRU
1. Check RIO cable
Location: U0.1-P1.1/Q2
2. Primary RIO adapter
Location: U0.1-P1.1
Primary RIO adapter
Location: U0.1-P1.1
1. RIO adapter
Location: U0.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
1. RIO adapter
Location: U0.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
1. RIO adapter
Location: U0.1-P1.1
2. Primary I/O backplane
Location: U0.1-P1
CEC backplane
Location: U1.1-P1
All processors
Location: U1.1-P1-C1
All memory
Locations:
U1.1-P1-C1
U1.1-P1-M1
U1.1-P1-M2.
Go to "MAP 1540: Minimum
Configuration" on page 113 and run
CEC drawer minimum configuration
to isolate the failing memory
component.
Update system firmware
1. Check for AIX updates
2. Check for system firmware
update
Check for system firmware update
Chapter 5. Error Code to FRU Index