System Power Control Menu

This menu is used to set power control options. Other menus that control boot options
are available here:
1. Enable/Disable Unattended Start Mode:
2. Ring-Indicate Power-On Menu
3. Reboot/Restart Policy Setup Menu
4. Power-On System
5. Power-Off System
6. Enable/Disable Fast System Boot
7. Boot Mode Menu
98. Return to Previous Menu
99. Exit from Menus
1>
v Enable/Disable Unattended Start Mode
Use this option to instruct the service processor to restore the power state of the
server after a temporary power failure. Unattended start mode can also be set
through the System Management Services (SMS) menus. It is intended to be used
on servers that require automatic power-on after a power failure. For more
information, see "System Power-On Methods" on page 398.
v Ring-Indicate Power-On Menu
30. Refresh Modem Settings
98. Return to Previous Menu
Ring-indicate is enabled by default on both serial port 1 (S1) and serial port 2 (S2).
When ring-indicate power-on is enabled, call-in is disabled.
If ring-indicate power-on is enabled and call-in is already enabled, you will be asked
to confirm your choice. Refer to the message displayed on your screen.
378
Service Guide
SYSTEM POWER CONTROL MENU
Currently Enabled
Currently Enabled
RING-INDICATE POWER-ON MENU
1. Ring-indicate power-on :
Currently Enabled
2. Number of rings:
Currently 3