Table 6. Service Processor Error Codes. (continued)
252
Service Guide
Error Code Description
406C 0300 IPL test detected processor card fault Processor card
406C 0301 IPL test detected memory DIMM fault Memory DIMM
406C 0302 IPL test detected memory DIMM fault Memory DIMM
406C 030D IPL test detected memory DIMM fault Memory DIMM
406C 0311 IPL test detected memory DIMM fault Memory DIMM
406C 0312 IPL test detected memory DIMM fault Memory DIMM
406C 031D IPL test detected memory DIMM fault Memory DIMM
406C 0321 IPL test detected memory DIMM fault Memory DIMM
406C 0322 IPL test detected memory DIMM fault Memory DIMM
406C 032D IPL test detected memory DIMM fault Memory DIMM
406C 0331 IPL test detected memory DIMM fault Memory DIMM
406C 0332 IPL test detected memory DIMM fault Memory DIMM
406C 033D IPL test detected memory DIMM fault Memory DIMM
406C 03FF IPL detected memory on processor
card fault
406C 3101 IPL detected RIO port 0 fault
Action/
Possible Failing FRU
Location: U1.1-P1-C1
Note: If this error occurs on a model
6H0, first verify that the correct type
of processor card is installed in the
system. Up to four processor are
supported in a model 6H0 system; if
a 6-way processor is plugged into the
system, this error code will be
generated and the system will not
boot.
Location: U1.1-P1-C1-M8
Location: U1.1-P1-C1-M1
Location: U1.1-P1-C1-M1 x2
Location: U1.1-P1-C1-M7
Location: U1.1-P1-C1-M2
Location: U1.1-P1-C1-M2 x2
Location: U1.1-P1-C1-M6
Location: U1.1-P1-C1-M3
Location: U1.1-P1-C1-M3 x2
Location: U1.1-P1-C1-M5
Location: U1.1-P1-C1-M4
Location: U1.1-P1-C1-M4 x2
Memory failure on processor card
that cannot be automatically isolated.
Go to "MAP 1540: Minimum
Configuration" on page 113, and run
CEC drawer minimum configuration
for further isolation.
1. Processor card
Location: U1.1-P1-C1
2. CEC drawer backplane
Location: U1.1-P1