Table 5. Firmware Error Codes. (continued)
192
Service Guide
Error Code Description
20A8 0002 Cannot get gateway IP address
20A8 0003 Cannot get server hardware address
20A8 0004 Bootup failed
20A80005 File transmission (TFTP) failed.
20A8 0006 Boot image too large
20D0 000F Self-test failed on device, no error
and/or location code information
available
20D0 0010 Self-test failed on device, cannot
locate package
20D0 0011 Firmware RTAS attempt to allocate
memory failed.
20E0 0001 Privileged-access password entry
error.
20E0 0004 Battery drained or needs replacement 1. Replace battery.
20E0 0009 Invalid password entered - system
locked
20EE 0003 IP parameter requires 3 dots "."
20EE 0004 Invalid IP parameter
20EE 0005 Invalid IP parameter (>255)
Action/
Possible Failing FRU
Refer to Table 2 on page 148 using
code E174.
Refer to Table 2 on page 148 using
code E174.
Refer to Table 2 on page 148 using
code E175.
Check network connection, try again.
Contact your next level of support for
assistance.
Refer to note "AIX and Physical
Location Code Reference Tables" on
page 36 to see if a location code is
available for the device the error was
reported against.
1. Replace device indicated by the
location code (if available).
2. Go to "MAP 1540: Minimum
Configuration" on page 113
Contact your service support
representative for assistance.
Contact your next level of support for
assistance.
The password has been entered
incorrectly. Retry installing the
password.
2. Replace primary I/O backplane
Location: U0.1-P1
The password has been entered
incorrectly 3 times.
Turn off, then turn on the system unit,
then enter the password correctly.
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid IP parameter.
Example: 255.192.002.000