Table 6. Service Processor Error Codes. (continued)
Error Code Description
4608 303A I/O system and other bus processor
runtime diagnostics detected 1GB
DIMM fault
4608 51AA I/O system and other bus processor
runtime diagnostics detected 645W
AC power supply fault
4608 51AB I/O system and other bus processor
runtime diagnostics detected 645W
DC power supply fault
4608 51AC I/O system and other bus processor
runtime diagnostics detected 595W
AC power supply fault
4608 51AD I/O system and other bus processor
runtime diagnostics detected 595W
DC power supply fault
4609 244C I/O system and memory test detected
1W processor fault
4609 244D I/O system and memory test detected
2W processor fault
4609 244E I/O system and memory test detected
4W processor fault
4609 244F I/O system and memory test detected
1W processor fault
4609 248B I/O system and memory test detected
primary I/O drawer operator panel
4609 24A1 I/O system and memory test detected
1W processor fault
4609 24A2 I/O system and memory test detected
2W processor fault
4609 24A3 I/O system and memory test detected
4W processor fault
4609 24A4 I/O system and memory test detected
6W processor fault
4609 25BB I/O system and memory test detected
1W processor card fault
4609 25BD I/O system and memory test detected
2W processor card fault
Action/
Possible Failing FRU
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
645W AC power supply
Locations:
U1.1-V1
U1.1-V2
645W DC power supply
Locations:
U1.1-V1
U1.1-V2
595W AC power supply
Locations:
U0.1-V1
U0.1-V2
595W DC power supply
Locations:
U0.1-V1
U0.1-V2
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Operator panel
Location: U0.1-L1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
Processor card
Location: U1.1-P1-C1
1W Processor card
Location: U1.1-P1-C1
2W Processor card
Location: U1.1-P1-C1
Chapter 5. Error Code to FRU Index