Table 6. Service Processor Error Codes. (continued)
Error Code Description
4B2D 283A Processor system and attention
handler detected CEC backplane
fault
4B2D 285D Processor system and attention
handler detected fan controller card
fault
4B2D 288D Processor system and attention
handler detected memory riser fault
4B2D 2A00 Processor system and attention
handler detected 6W processor fault
4B2D 300A Processor system and attention
handler detected 32MB DIMM fault
4B2D 300B Processor system and attention
handler detected 128MB DIMM fault
4B2D 300C Processor system and attention
handler detected 256MB DIMM fault
4B2D 300D Processor system and attention
handler detected 512MB (stacked)
DIMM fault
4B2D 300E Processor system and attention
handler detected 512MB (unstacked)
DIMM fault
Action/
Possible Failing FRU
1. Processor card
Location: U1.1-P1-C1
2. CEC backplane
Location: U1.1-P1
Fan controller card
Locations:
U0.1-X2
U1.1-X2
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
Processor card
Location: U1.1-P1-C1
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
Chapter 5. Error Code to FRU Index