System Firmware Update Messages; Common Firmware Error Codes - IBM 7026-H80 - RS/6000 - 256 MB RAM Service Manual

Service guide
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)

System Firmware Update Messages

Table 7. System Firmware Update Messages

Common Firmware Error Codes

Attention:
page 165. If you replace FRUs or perform an action and the problem is still not
corrected, go to "MAP 1540: Minimum Configuration" on page 113 unless otherwise
indicated in the tables.
354
Service Guide
Error Code Description
4B2F 303A Processor system and error code
generation/logging detected 1GB
DIMM fault
4B2F 51AA Processor system and error code
generation/logging detected 645W
AC power supply fault
4B2F 51AB Processor system and error code
generation/logging detected 645W
DC power supply fault
4B2F 51AC Processor system and error code
generation/logging detected 595W
AC power supply fault
4B2F 51AD Processor system and error code
generation/logging detected 595W
DC power supply fault
Error Code Description
A1FD 0000 Recovery mode entered
A1FD 0001 Service processor flash recovery
A1FD 0002 Service processor flash recovery
A1FD 0003 Service processor flash recovery
A1FD 0004 Service processor flash recovery
Follow the procedure defined in "Checkpoint and Error Code Index" on
Action/
Possible Failing FRU
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
645W AC power supply
Locations:
U1.1-V1
U1.1-V2
645W DC power supply
Locations:
U1.1-V1
U1.1-V2
595W AC power supply
Locations:
U0.1-V1
U0.1-V2
595W DC power supply
Locations:
U0.1-V1
U0.1-V2
Action/
Possible Failing FRU
Information message
Insert Diskette #1
Insert Diskette #2
Insert Diskette #3
Insert Diskette #4

Advertisement