enclosures, refer to the documentation included with each
enclosure.
The following information is provided to help you properly connect
your enclosure to the HP NetRAID-4M:
All rules for SCSI ID and termination (discussed on page 2-14)
must be followed when installing SCSI devices in an array
enclosure. The ID settings for the drives in the enclosure are
determined by the slot, so drive ID jumpers should be
removed.
The cable you use to connect the array enclosure to the
HP NetRAID-4M must be equipped with a very high-density
68-pin connector.
Ideally, the array enclosure itself should provide termination
capability, and you should disable termination on all the drives
in the enclosure.
If the enclosure you are using for the array drives is not
specifically designed as an array enclosure (such as a standard
tower unit), be sure it has adequate cooling and ventilation.
Array Enclosure
Figure 2-9. Typical Dual-channel Array Enclosure Setup
2-12