Hewlett-Packard NetRAID-4M Controller Installation Guide
b
Change your working directory by entering the following
command:
cd /mnt/cdrom/periph/nraidadp/linux/us
c
Copy the hpnapps.tar file to /tmp by entering the following
command:
cp hpnapps.tar /tmp
d
Change your working directory by entering the following
command:
cd /tmp
e
Untar the file hpnapps.tar archive by entering the following
command:
tar -xvf hpnapps.tar
The tar command will report that it untarred a file in the
format hpnapps-VERSION_NUMBER.rpm. You will use
this filename as an argument in the next step.
f
Install the UNIX Controller Management Software on your
Linux system by entering the following command,
replacing VERSION_NUMBER with the actual version of
the software:
rpm -i hpnapps-VERSION_NUMBER.rpm
g
Unmount the cdrom by entering the following command:
umount /mnt/cdrom
Openserver
a
Place the Navigator cdrom which contains the UNIX
Controller Management Software in the cdrom drive.
The operating system may automount the cdrom on
/mnt/cdrom. If not, do the following:
i
Create the mount point by entering the following
command:
mkdir /mnt/cdrom
ii
Mount the cdrom on /mnt/cdrom by entering a
command like the following, replacing CDROM_LUN
with the logical unit number of your cdrom device (note
that in most cases the default cdrom lun is cd0):
5-8