Command Syntax; Command Names And Parameters; Disks - HP P2000 Reference Manual

Msa system
Hide thumbs Also See for P2000:
Table of Contents

Advertisement

<PROPERTY name="configured-speed">Auto</PROPERTY>
<PROPERTY name="configured-speed-numeric">3</PROPERTY>
<PROPERTY name="health">N/A</PROPERTY>
<PROPERTY name="health-numeric">4</PROPERTY>
<PROPERTY name="health-reason">Host port is down.</PROPERTY>
<OBJECT basetype="fc-port" name="port-details" oid="2" format="rows">
</OBJECT>
</OBJECT>
<OBJECT basetype="port" name="name" oid="3" format="rows">
<PROPERTY name="durable-id">hostport_A2</PROPERTY>
...
</OBJECT>
<OBJECT basetype="status" name="status" oid="5">
<PROPERTY name="response-type">Success</PROPERTY>
<PROPERTY name="response-type-numeric">0</PROPERTY>
<PROPERTY name="response">Command completed successfully.</PROPERTY>
<PROPERTY name="return-code">0</PROPERTY>
<PROPERTY name="component-id"></PROPERTY>
<PROPERTY name="time-stamp">2010-08-10 12:11:10</PROPERTY>
<PROPERTY name="time-stamp-numeric">1281442270</PROPERTY>
</OBJECT>
</RESPONSE>

Command syntax

Command names and parameters

Command and parameter names are not case sensitive.
Parameters enclosed in square brackets ([]) are optional. Do not type the bracket characters.
Parameter values separated by '|' characters are options. Enter only one of the values. These values are
not case sensitive.
Parameter values in italics are variables. Substitute text that is appropriate for the task you want to perform.
Variable values such names of users and volumes are case sensitive and have a maximum length in bytes.
ASCII characters are 1 byte; most Latin (Western European) characters with diacritics are 2 bytes; most
Asian characters are 3 bytes.
Unless otherwise specified, a parameter value can include printable UTF-8 characters except angle
brackets (<>), backslash (\), comma (,), and double quotes ("). A parameter value that includes a space
must be enclosed in double quotes.
Parameters can be entered in any order. However, if the value of a parameter with no keyword is the same
as the keyword of an optional parameter, the optional parameter must precede the value. For example, to
create a vdisk named spare, the spare parameter must precede the name value spare:
create vdisk level raid5 disks 1.10-12 spare 1.7 spare

Disks

Disks are specified by enclosure ID and slot number. Enclosure IDs increment from 1. Disk IDs increment
from 1 in each enclosure. You can specify:
A disk. Example: 1.4
A hyphenated range of disks. Example: 1.4-7
A comma-separated list of individual disks, ranges, or both (with no spaces). Example: 1.4,1.6-9
A RAID 10 or 50 vdisk, with disks in sub-vdisks separated by colons (with no spaces). RAID-50
example: 1.1-3:1.4-6:1.7,1.10-11
<PROPERTY name="configured-topology">Loop</PROPERTY>
<PROPERTY name="primary-loop-id"></PROPERTY>