HP P2000 Reference Manual page 167

Msa system
Hide thumbs Also See for P2000:
Table of Contents

Advertisement

session-preferences
Optional. Specifies that the current CLI settings will become permanent settings for the user.
storage-size-base 2|10
Optional. Alias for base.
storage-size-precision #
Optional. Alias for precision.
storage-size-units auto|MB|GB|TB
Optional. Alias for units.
temperature-scale celsius|c|fahrenheit|f
Optional. Specifies to use the Celsius scale or Fahrenheit scale for temperature values.
timeout #
Optional. Sets the timeout value in seconds for the login session. Valid values are 120–43200
seconds (2–720 minutes). The default is 1800 seconds (30 minutes).
type novice|standard|advanced|diagnostic
Optional. Specifies the user's level of technical expertise. The default is standard. All user types
have access to all commands.
units auto|MB|GB|TB
Optional. Sets the unit for display of storage-space sizes. auto lets the system determine the proper
unit for a size. Based on the precision setting, if the selected unit is too large to meaningfully
display a size, the system uses a smaller unit for that size. For example, if units is set to TB,
precision is set to 1, and base is set to 10, the size 0.1 1709 TB is instead shown as 1 17.1 GB. The
default is auto.
user-name
Specifies the user profile to change. Names are case sensitive.
Example Change the temperature scale and accessible interfaces for user jsmith:
# set user jsmith temperature-scale f interfaces wbi,cli
Success: Command completed successfully. - The settings were changed
successfully.
Change the password for user JDoe:
# set user JDoe password Abc%123
Success: Command completed successfully. - The settings were changed
successfully.
See also
• set password
• show users
HP P2000 G3 MSA System CLI Reference Guide 167

Advertisement

Table of Contents
loading

This manual is also suitable for:

P2000 g3

Table of Contents