Enclosure-Fru - HP P2000 Reference Manual

Msa system
Hide thumbs Also See for P2000:
Table of Contents

Advertisement

enclosure-fru

Properties
Table 26
enclosure-fru properties
Name
name
description
part-number
serial-number
revision
dash-level
fru-shortname
mfg-date
mfg-date-
numeric
mfg-location
mfg-vendor-id
fru-location
configuration-
serialnumber
fru-status
Example
# show frus
...
<OBJECT basetype="enclosure-fru" name="fru" oid="1" format="pairs">
<PROPERTY name="name" type="string">CHASSIS_MIDPLANE</PROPERTY>
<PROPERTY name="description" type="string">description</PROPERTY>
<PROPERTY name="part-number" type="string">490095-001</PROPERTY>
<PROPERTY name="serial-number" key="true" type="string">SN</PROPERTY>
<PROPERTY name="revision" type="string">B</PROPERTY>
<PROPERTY name="dash-level" type="string"></PROPERTY>
<PROPERTY name="fru-shortname" type="string">Midplane/Chassis</PROPERTY>
330 XML API basetype properties
Type
Description
FRU name.
string
CHASSIS_MIDPLANE: 2U chassis and midplane circuit board
RAID_IOM: Controller module
IOM: Expansion module
POWER_SUPPLY: Power supply module
FRU long description.
string
FRU part number.
string
FRU serial number.
string
OEM hardware-revision level for the FRU.
string
FRU template revision number.
string
FRU short description.
string
Date and time, in the format year-month-day hour:minutes:seconds
string
(UTC), when a PCBA was programmed or a power supply module was
manufactured.
Unformatted mfg-date value.
string
City, state/province, and country where the FRU was manufactured.
string
JEDEC ID of the FRU manufacturer.
string
Location of the FRU in the enclosure.
string
MID-PLANE SLOT: Chassis midplane.
UPPER IOM SLOT: Controller module or expansion module A.
LOWER IOM SLOT: Controller module or expansion module B.
LEFT PSU SLOT: Power supply module on the left, as viewed from the
back.
RIGHT PSU SLOT: Power supply module on the right, as viewed from the
back.
Configuration serial number.
string
FRU status.
string
Absent: Component is not present.
Fault: At least one subcomponent has a fault.
OK: All subcomponents are operating normally.
Not Available: Status is not available.