Fan Failure
Shows whether the cache policy automatically changes to write-through when a fan fails.
Temperature Exceeded
Shows whether the system forces a controller shutdown when a temperature is detected that exceeds
system threshold limits.
Partner Notify
Shows whether the partner controller is notified when a trigger condition occurs.
Auto Write Back
Shows whether the cache mode automatically changes to write-back after the trigger condition is
cleared.
Drive Spin Down Non-Vdisk Enable
Shows whether available disks and global spares will spin down after a period of inactivity shown
by the Drive Spin Down Non-Vdisk Delay field.
Drive Spin Down Non-Vdisk Delay
Specifies the period of inactivity after which available disks and global spares automatically spin
down, from 1–360 minutes, or 0 if spin-down is disabled.
Disk Background Scrub
Shows whether disks that are not in vdisks are automatically checked for disk defects to ensure
system health.
Example Show advanced system-configuration settings:
# show advanced-settings
Vdisk Background Scrub: Enabled
Vdisk Background Scrub Interval: 24
Partner Firmware Upgrade: Disabled
Utility Priority: High
SMART: Enabled
Dynamic Spare Configuration: Disabled
Enclosure Polling Rate: 5
Host Control of Caching: Enabled
Sync Cache Mode: Immediate
Missing LUN Response: Not Ready
Controller Failure: Disabled
Supercap Failure: Enabled
CompactFlash Failure: Enabled
Power Supply Failure: Disabled
Fan Failure: Disabled
Temperature Exceeded: Disabled
Partner Notify: Disabled
Auto Write Back: Enabled
Drive Spin Down Non-Vdisk Enable: Enabled
Drive Spin Down Non-Vdisk Delay: 30
Disk Background Scrub: Disabled
Basetypes
• advanced-settings-table
• status
See also
• set advanced-settings
HP P2000 G3 MSA System CLI Reference Guide 171