events
Properties
Table 29
events properties
Name
time-stamp
time-stamp-
numeric
event-code
event-id
model
serial-number
controller
controller-
numeric
severity
severity-
numeric
message
Example
# show events
...
<OBJECT basetype="events" name="event" oid="2" format="packed">
<PROPERTY name="time-stamp" type="string">2010-10-28 11:58:47</PROPERTY>
<PROPERTY name="time-stamp-numeric" type="string">1288267127</PROPERTY>
<PROPERTY name="event-code" type="string">153</PROPERTY>
<PROPERTY name="event-id" type="string">A39873</PROPERTY>
<PROPERTY name="model" type="string">P2000 G3 iSCSI</PROPERTY>
<PROPERTY name="serial-number" type="string">SN</PROPERTY>
<PROPERTY name="controller" type="string">A</PROPERTY>
<PROPERTY name="controller-numeric" type="string">1</PROPERTY>
<PROPERTY name="severity" type="string">INFORMATIONAL</PROPERTY>
<PROPERTY name="severity-numeric" type="string">0</PROPERTY>
<PROPERTY name="message" type="string">The Storage Controller resumed communications
with the Management Controller.</PROPERTY>
</OBJECT>
...
Type
Description
Date and time, in the format year-month-day hour:minutes:seconds
string
(UTC), when this event was detected.
Unformatted time-stamp value.
string
Event code. For event-code descriptions, see the Event Descriptions Reference
string
Guide.
Event ID.
string
Controller model.
string
Controller serial number.
string
•
A: Controller A.
string
•
B: Controller B.
Numeric equivalents for controller values.
string
•
0: B
•
1: A
Event severity.
string
•
CRITICAL: A failure occurred that may cause a controller to shut down.
Correct the problem immediately.
•
ERROR: A failure occurred that may affect data integrity or system stability.
Correct the problem as soon as possible.
•
WARNING: A problem occurred that may affect system stability but not data
integrity. Evaluate the problem and correct it if necessary.
•
INFORMATIONAL: A configuration or state change occurred, or a problem
occurred that the system corrected. No action is required.
Numeric equivalents for severity values.
string
•
0: INFORMATIONAL
•
1: WARNING
•
2: ERROR
•
3: CRITICAL
Message giving details about the event.
string
HP P2000 G3 MSA System CLI Reference Guide 337