Verify Vdisk - HP P2000 Reference Manual

Msa system
Hide thumbs Also See for P2000:
Table of Contents

Advertisement

verify vdisk

Description Verifies whether vdisk redundancy data is consistent with its user data. For RAID 3, 5, 6, and 50,
verify checks all parity blocks to find data-parity mismatches. For RAID 1 and 10, verify compares
the primary and secondary disks to find data inconsistencies.
Verification can last over an hour, depending on vdisk size, utility priority, and amount of I/O
activity. When verification is complete, the number of inconsistencies found is reported with event
code 21 (Vdisk verification complete) in the event log. Such inconsistencies can indicate
that a disk in the vdisk is going bad. You can use a vdisk while it is being verified.
Syntax
verify vdisk vdisks [fix yes|no]
Parameters vdisks
Names or serial numbers of the vdisks to verify. For vdisk syntax, see
fix yes|no
Optional. Specifies to verify data in the vdisk and to fix any parity errors by making parity match the
data in all cases. For details about using this parameter, including the required pass code, see the
topic about resolving scrub errors in the Event Descriptions Reference Guide.
Example Verify vdisk vd1:
# verify vdisk vd1
Info: Command completed successfully. (vd1) - The verify was started on vdisk
vd1.
See also
• abort verify
• show vdisks
Command syntax
HP P2000 G3 MSA System CLI Reference Guide 283
on page 21.