HP P2000 Reference Manual page 120

Msa system
Hide thumbs Also See for P2000:
Table of Contents

Advertisement

fan-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a fan fails.
host-cache-control enabled|disabled|on|off
Optional. Sets whether the host can modify the cache setting. The default is disabled.
missing-lun-response notready|illegal
Optional. Sets the missing-LUN response which enables the host drivers to continue probing for LUNs
until they reach the LUN to which they have access.
notready: Sends a reply that there is a LUN where a gap has been created but that it's not
ready. Sense data returned is sensekey = 2, code = 4, qualifier = 3. This option is the default.
illegal: Sends a reply that there is a LUN but that the request is illegal. Sense data returned is
sensekey = 5, code = 25h, qualifier = 0.
partner-firmware-upgrade enabled|disabled|on|off
Optional. Sets whether component firmware versions are monitored and will be automatically
upgraded on the partner controller.
partner-notify enabled|disabled|on|off
Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this
option to have the partner also change to write-through mode for better data protection. Disable this
option to allow the partner continue using its current caching mode for better performance. The
default is disabled.
power-supply-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a power
supply fails.
smart enabled|disabled|on|off|detect-only
Optional. Enables or disables SMART (Self-Monitoring Analysis and Reporting Technology)
monitoring for all disks in the storage system. Each disk added after detect-only is set retains its
SMART setting. Enabled by default.
super-cap-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when cache backup
power is not fully charged or fails.
sync-cache-mode immediate|flush
Optional. Sets the option that controls how the SCSI SYNCHRONIZE CACHE command is handled.
immediate: Good status is returned immediately and cache content is unchanged. This option
is the default.
flush: Good status is returned only after all write-back data for the specified volume is flushed
to disk.
temperature-exceeded enabled|disabled|on|off
Optional. Sets whether the system forces a controller shutdown if a temperature is detected that
exceeds system threshold limits.
utility-priority low|medium|high
Optional. Sets the priority at which jobs (such as vdisk verification and reconstruction but not
background scrub) run with respect to I/O operations competing for the system's processors: low,
medium, or high.
spin-down
Optional. Enables or disables drive spin-down (DSD) for available disks and global spares. Disabled
by default.
spin-down-delay delay
Optional. Sets the period of inactivity after which available disks and global spares automatically
spin down, from 1–360 minutes. DSD is enabled by a value in this range, or is disabled by the value
0. If DSD is enabled and no delay value is set, the default is 15 minutes.
120 Alphabetical list of commands

Advertisement

Table of Contents
loading

This manual is also suitable for:

P2000 g3

Table of Contents