Chapter 5
Figure 5-6. Memory Board DC-to-DC Converters

Installing the Processor/Memory Complex

To replace the Processor/Memory Complex, complete the following procedure:
1. Orient the Processor/Memory Complex so that the high density connector
is positioned to slide into the Processor/Memory Bay and connect to the
Sideplane board.
2. With the two extraction levers on the top and pointed towards you, slide
the Complex into the bay.
3. Push the extraction levers toward the chassis so that they are engaged at
the same time, seating the Complex into the Sideplane board.
4. Fasten the four screws on the left side of the chassis to hold the
Processor/Memory Complex in place.
5. Locate the Processor/Memory Complex Cover and orient it such that the
right side of the cover is just to the left of the right side of the bay.
6. Press the cover's edge past the chassis and slide the cover to the right such
that the edge of the cover slips in behind the chassis frame.
7. Press the left side of the cover toward the chassis and secure the two
screws at the left of the cover.
8. Slide the unit into the rack.
52
Installing Additional Memory