Chapter 10
Power Setup
The Power setup page is used to configure these power features:
Power Feature
Power Restore Policy
Power Restore Delay
Power Cycle Delay
Fault Resilient Booting (FRB) Setup
Fault Resilient Booting (FRB) allows a multiprocessor system to boot in case the
bootstrap processor (BSP) fails.
FRB3 Timeout
FRB3 refers to the level of FRB in which a timer is started at system power up or
hard reset. The BIOS stops this timer in the power-on self test (POST) by
asserting the FRB timer halt signal to the BMC. If the timer is not stopped, the
BSP is disabled, the system is reset and another processor becomes the BSP.
This edit box lets you set the FRB3 timeout in seconds. The range is 0 to 65535
seconds.
116
Configuring the HP Server
Description
Determines what happens when the system
loses and then regains AC power. The
choices are:
Always on: The system is powered on
after AC power is restored.
Always off: The system will be left
powered off after AC power is
restored.
Restore Power state: The system is
restored to its previous on or off state
before AC power was lost. This is the
default.
The delay in seconds before the power
restore policy is enacted. The range is 0 to
15 seconds.
The delay in seconds between power cycles.
The range is 0 to 255 seconds, where 0 is the
default value. For this period of time after the
system is turned off, the BMC ignores the
front panel power switch if anyone attempts
to turn the system back on.