Hot Swapping the 172 mm Fans

The four 172 mm cooling fans are mounted in pairs on each side of the chassis.
You can hot-swap these fans without turning the server system power off. Each
fan uses an amber LED located on the fan's casing to indicate the fan has
failed. If it is a failed fan, the amber LED will be illuminated on the front panel,
and the amber LED on the failed fan itself will be illuminated. The individual fan
LEDs may be seen through view-ports in the fan covers

Removing the 172 mm Fans

To remove the 172 mm fan, complete the following steps:
1. Observe all standard safety and ESD precautions.
2. Slide the server out of the rack far enough to expose the fan-access doors
near the front sides of the chassis.
CAUTION
Do not leave the door open for an extended time. Cooling of
the system could be reduced.
3. Slide the plastic latch on the fan cover upwards and pull the door open.
4. Grasp the fan assembly with the finger holes and pull it out.